Testimonials

It is very nice to visit Lambda facility and thanks to warm welcome provided by all the teams. I can easily say one of the best CRO I ever visited. People here are wonderful and doing great job

Reputed Client of Israel

Awesome hospitality & fantastic office. All the best!

Reputed Client of Japan

Excellent hospitality and cooperation received throughout the audit. People are knowledgeable and extremely transparent. Looking for long time relation

Reputed Client of Asia

Facility is too good to conduct the BABE studies and adherence to protocol and quality assurance in conducting studies are meeting sponsor expectations and requirements.

Reputed Client of India

Facility is good, people r trained well and know the subject on which they r working. All the best.

Reputed Client of USA

Highly innovative and advanced research centre that possess bright future for the development of the country.

Reputed International Government Body

It is one of the best facility in India for BA/BE

Reputed Regulatory Authority

Lambda is a very professional CRO. All the staff here are experienced and very knowledgeable. I'm grateful for their accommodations and hospitality. The future, if we want to carry out BE study, we will ask Lambda help again.

Reputed Client of Europe

It was a really pleasant meeting with the PV department, and I am looking forward to the next visit.

Reputed Client of Europe

Amazing and best CRO I ever seen

Reputed Client of China

Blog

Blog

Home / Blog

A highly sensitive LC-MS/MS method for the simultaneous quantification of Nitroglycerin and its two major metabolites in human plasma

30 Apr 2019

A highly sensitive LC-MS/MS method for the simultaneous quantification of Nitroglycerin and its two major metabolites in human plasma

Structure: 
            

Introduction: 
Nitroglycerin is a colorless, oily, explosive liquid produced by nitrating glycerol. Nitroglycerin forms free radical nitric oxide which activates guanylate cyclase, resulting in an increase of guanosine 3’5’monophosphate in smooth muscle and other tissues. These events lead to dephosphorylation of myosin light chain, which regulate the contractile state in smooth muscle and result in vasodilatation.   It is used to prevent chest pain (angina) in people with a certain heart condition (coronary artery disease). 

Selective and highly sensitive methods at a LLOQ of about 20 pg/mL for Nitroglycerin, 40 pg/mL for both active metabolites i.e 1, 2 dinitroglycerin and 1, 3 dinitroglycerin are required for their estimations in human plasma. This was accomplished with the new method developed at our end.

Method: Briefly, the method for the quantification of Nitroglycerin, 1, 2 dinitroglycerin and 1, 3 dinitroglycerin involves solid phase extraction using Nitroglycerin-d5, 1, 2 dinitroglycerin-d5 and 1, 3 dinitroglycerin-d5 as internal standards (ISTD).  Chromatographic separation of the drug and both metabolites were achieved on C8 column with a mobile phase consisting of ammonium chloride in methanol and ammonium chloride in water, with gradient time program, and a total run-time of 11 minutes with adequate separation between the drug and metabolites. 

This new method was validated in terms of linearity, stabilities, carry-over effect, reinjection reproducibility, precision, accuracy and selectivity. The linearity ranged from 20 to 4000 pg/mL for nitroglycerin and 40 to 8000 pg/mL for both metabolites. As nitroglycerin and its two metabolites are unstable in blood, buffered blood and plasma was used for establishing stability and was found to be stable in plasma under the assay condition. Moreover, the method exhibited good precision and accuracy with precision even at the lower level of quantification. Also, there was no matrix effect observed in normal human lots and no inter-conversion issues.

This validated method is suitable for the analysis of samples from a single oral dose of 0.6 mg Nitroglycerin sublingual tablets in humans under fasting conditions, and will be applied to the analysis of study samples.

Conclusion: A selective, precise, accurate and highly sensitive LC-MS/MS method is now available for the simultaneous quantification of Nitroglycerin, 1, 2 dinitroglycerin and 1, 3 dinitroglycerin in human plasma.
 